Technical specifications
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Rated voltage
690 - 690V
Overload release current setting
800.0 - 2000A
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
3
Complete device with protection unit
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
1200.0 - 1200.0A
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Yes
With switched-off indicator
Yes
Integrated earth fault protection
Yes
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
From same serie
1SDA056647R1 | E3V 2000 PR123/P-LSIG IN=2000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Rated voltage
690 .. 690V
Overload release current setting
800.0 .. 2000A
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Number of poles
3
Complete device with protection unit
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
1200.0 .. 1200.0A
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
With switched-off indicator
Integrated earth fault protection
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
From same serie