Aleta.hr
Main Product Image

1SDA056652R1 | E3V 2000 PR122/P-LSI IN=2000A 4P W MP

Code: 1593239

ManufacturerRAZNO
Catalog number1SDA056652R1
Type
EAN code8015644579920

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

2000A

Integrated earth fault protection

No

Type of electrical connection of main circuit

Connection at separate chassis part

Suitable for DIN rail (top hat rail) mounting

No

Overload release current setting

800.0 - 2000A

Rated voltage

690 - 690V

With switched-off indicator

Yes

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Position of connection for main current circuit

Connection at separate chassis part

Device construction

Built-in device slide-in technique (withdrawable)

Adjustment range undelayed short-circuit release

3000.0 - 30000A

With under voltage release

No

Number of poles

4

Type of control element

Push button

Motor drive integrated

No

Degree of protection (IP)

IP30

Adjustment range short-term delayed short-circuit release

1200.0 - 1200.0A

Number of auxiliary contacts as change-over contact

4

Motor drive optional

Yes

DIN rail (top hat rail) mounting optional

No

Complete device with protection unit

Yes

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SDA056652R1 | E3V 2000 PR122/P-LSI IN=2000A 4P W MP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

2000A

Integrated earth fault protection

Type of electrical connection of main circuit

Connection at separate chassis part

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

800.0 .. 2000A

Rated voltage

690 .. 690V

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Position of connection for main current circuit

Connection at separate chassis part

Device construction

Built-in device slide-in technique (withdrawable)

Adjustment range undelayed short-circuit release

3000.0 .. 30000A

With under voltage release

Number of poles

4

Type of control element

Push button

Motor drive integrated

Degree of protection (IP)

IP30

Adjustment range short-term delayed short-circuit release

1200.0 .. 1200.0A

Number of auxiliary contacts as change-over contact

4

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.