Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
1280.0 - 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
Rated permanent current Iu
3200A
Type of control element
Push button
Number of poles
4
Motor drive optional
Yes
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
1920.0 - 1920.0A
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Rated voltage
690 - 690V
Complete device with protection unit
Yes
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
From same serie
1SDA056717R1 | E3V 3200 PR122/P-LSIG IN=3200A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
1280.0 .. 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
Rated permanent current Iu
3200A
Type of control element
Push button
Number of poles
4
Motor drive optional
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
1920.0 .. 1920.0A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Rated voltage
690 .. 690V
Complete device with protection unit
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
From same serie