Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Degree of protection (IP)IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz130kA
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
Overload release current setting1000.0 - 2500A
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release1500.0 - 1500.0A
Number of auxiliary contacts as change-over contact4
Adjustment range undelayed short-circuit release3750.0 - 37500A
Type of control elementPush button
Rated permanent current Iu2500A
With switched-off indicatorYes
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Position of connection for main current circuitBack side
Integrated earth fault protectionYes
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056759R1 | E3L 2500 PR123/P-LSIG IN=2500A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Degree of protection (IP)

IP30

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

Overload release current setting

1000.0 .. 2500A

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

1500.0 .. 1500.0A

Number of auxiliary contacts as change-over contact

4

Adjustment range undelayed short-circuit release

3750.0 .. 37500A

Type of control element

Push button

Rated permanent current Iu

2500A

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Position of connection for main current circuit

Back side

Integrated earth fault protection

Motor drive optional

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.