Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
1000.0 - 2500A
Rated voltage
690 - 690V
Integrated earth fault protection
No
Rated permanent current Iu
2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Type of control element
Push button
Motor drive integrated
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Adjustment range short-term delayed short-circuit release
2500 - 25000A
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Number of poles
3
From same serie
1SDA056769R1 | E3L 2500 PR121/P-LSI IN=2500A 3P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
1000.0 .. 2500A
Rated voltage
690 .. 690V
Integrated earth fault protection
Rated permanent current Iu
2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Type of control element
Push button
Motor drive integrated
Degree of protection (IP)
IP30
Complete device with protection unit
Adjustment range short-term delayed short-circuit release
2500 .. 25000A
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Number of poles
3
From same serie
We use cookies to enhance your experience.