Technical specifications
Rated voltage
690 - 690V
Rated permanent current Iu
2500A
Adjustment range short-term delayed short-circuit release
1500.0 - 1500.0A
Overload release current setting
1000.0 - 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA056781R1 | E3L 2500 PR122/P-LSIG IN=2500A 4P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 .. 690V
Rated permanent current Iu
2500A
Adjustment range short-term delayed short-circuit release
1500.0 .. 1500.0A
Overload release current setting
1000.0 .. 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Type of control element
Push button
Complete device with protection unit
Motor drive optional
Degree of protection (IP)
IP30