Rated permanent current Iu4000A
Number of poles3
Overload release current setting1600.0 - 4000A
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Number of auxiliary contacts as change-over contact4
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitBack side
Degree of protection (IP)IP30
Rated voltage690 - 690V
Type of control elementPush button
Adjustment range undelayed short-circuit release6000.0 - 60000A
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release2400.0 - 2400.0A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz75kA
Integrated earth fault protectionYes
With switched-off indicatorYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056791R1 | E4S 4000 PR123/P-LSIG IN=4000A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

4000A

Number of poles

3

Overload release current setting

1600.0 .. 4000A

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Back side

Degree of protection (IP)

IP30

Rated voltage

690 .. 690V

Type of control element

Push button

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

2400.0 .. 2400.0A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

75kA

Integrated earth fault protection

With switched-off indicator

Complete device with protection unit

DIN rail (top hat rail) mounting optional