Technical specifications
Rated permanent current Iu
4000A
Overload release current setting
1600.0 - 4000A
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Adjustment range short-term delayed short-circuit release
2400.0 - 2400.0A
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Type of control element
Push button
With switched-off indicator
Yes
Number of poles
3
Motor drive integrated
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
From same serie
1SDA056807R1 | E4S 4000 PR123/P-LSIG IN=4000A 3P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
4000A
Overload release current setting
1600.0 .. 4000A
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Adjustment range short-term delayed short-circuit release
2400.0 .. 2400.0A
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP30
Type of control element
Push button
With switched-off indicator
Number of poles
3
Motor drive integrated
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA