Technical specifications

Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range short-term delayed short-circuit release4000 - 40000A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release6000.0 - 60000A
Position of connection for main current circuitBack side
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact4
Number of poles3
Motor drive optionalYes
Rated permanent current Iu4000A
Degree of protection (IP)IP30
Overload release current setting1600.0 - 4000A
With switched-off indicatorYes
Type of control elementPush button
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056849R1 | E4H 4000 PR121/P-LSI IN=4000A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range short-term delayed short-circuit release

4000 .. 40000A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Position of connection for main current circuit

Back side

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Number of auxiliary contacts as change-over contact

4

Number of poles

3

Motor drive optional

Rated permanent current Iu

4000A

Degree of protection (IP)

IP30

Overload release current setting

1600.0 .. 4000A

With switched-off indicator

Type of control element

Push button