Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Overload release current setting1600.0 - 4000A
Number of poles3
Rated permanent current Iu4000A
Position of connection for main current circuitBack side
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP30
Number of auxiliary contacts as change-over contact4
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Type of control elementPush button
Integrated earth fault protectionYes
With switched-off indicatorYes
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Complete device with protection unitYes
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release2400.0 - 2400.0A
Adjustment range undelayed short-circuit release6000.0 - 60000A
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056853R1 | E4H 4000 PR122/P-LSIG IN=4000A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

1600.0 .. 4000A

Number of poles

3

Rated permanent current Iu

4000A

Position of connection for main current circuit

Back side

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP30

Number of auxiliary contacts as change-over contact

4

Motor drive integrated

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Type of control element

Push button

Integrated earth fault protection

With switched-off indicator

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Complete device with protection unit

Motor drive optional

Adjustment range short-term delayed short-circuit release

2400.0 .. 2400.0A

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.