Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuitBack side
Number of auxiliary contacts as change-over contact4
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP30
Overload release current setting1600.0 - 4000A
Number of poles3
Rated permanent current Iu4000A
Motor drive integratedNo
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Type of electrical connection of main circuitBolt connection
Type of control elementPush button
Adjustment range short-term delayed short-circuit release2400.0 - 2400.0A
Complete device with protection unitYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release6000.0 - 60000A
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionYes
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056855R1 | E4H 4000 PR123/P-LSIG IN=4000A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuit

Back side

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP30

Overload release current setting

1600.0 .. 4000A

Number of poles

3

Rated permanent current Iu

4000A

Motor drive integrated

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Type of electrical connection of main circuit

Bolt connection

Type of control element

Push button

Adjustment range short-term delayed short-circuit release

2400.0 .. 2400.0A

Complete device with protection unit

Motor drive optional

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.