Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact4
Overload release current setting1600.0 - 4000A
Degree of protection (IP)IP30
Motor drive integratedNo
Position of connection for main current circuitBack side
Rated voltage690 - 690V
Number of poles4
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu4000A
With switched-off indicatorYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release4000 - 40000A
Adjustment range undelayed short-circuit release6000.0 - 60000A
Type of control elementPush button
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056921R1 | E4V 4000 PR121/P-LSI IN=4000A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

4

Overload release current setting

1600.0 .. 4000A

Degree of protection (IP)

IP30

Motor drive integrated

Position of connection for main current circuit

Back side

Rated voltage

690 .. 690V

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

4000A

With switched-off indicator

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

4000 .. 40000A

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Type of control element

Push button

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.