Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
4000 - 40000A
Rated permanent current Iu
4000A
DIN rail (top hat rail) mounting optional
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
1600.0 - 4000A
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
No
Motor drive integrated
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
From same serie
1SDA056929R1 | E4V 4000 PR121/P-LSI IN=4000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
4000 .. 40000A
Rated permanent current Iu
4000A
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
1600.0 .. 4000A
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Motor drive integrated
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
From same serie