Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
4000A
Overload release current setting
1600.0 - 4000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range short-term delayed short-circuit release
2400.0 - 2400.0A
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Type of control element
Push button
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Motor drive integrated
No
From same serie
1SDA056943R1 | E4V 4000 PR123/P-LSIG IN=4000A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
4000A
Overload release current setting
1600.0 .. 4000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range short-term delayed short-circuit release
2400.0 .. 2400.0A
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Type of control element
Push button
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive optional
Degree of protection (IP)
IP30
Motor drive integrated
From same serie