Number of poles4
Overload release current setting2000.0 - 5000A
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Rated voltage690 - 690V
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Rated permanent current Iu5000A
Adjustment range short-term delayed short-circuit release3000.0 - 3000.0A
Number of auxiliary contacts as change-over contact4
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release7500.0 - 75000A
Integrated earth fault protectionYes
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056991R1 | E6H 5000 PR123/P-LSIG IN=5000A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Overload release current setting

2000.0 .. 5000A

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Rated voltage

690 .. 690V

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Rated permanent current Iu

5000A

Adjustment range short-term delayed short-circuit release

3000.0 .. 3000.0A

Number of auxiliary contacts as change-over contact

4

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

7500.0 .. 75000A

Integrated earth fault protection

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.