Technical specifications

Number of auxiliary contacts as change-over contact4
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu6300A
Overload release current setting2520.0 - 6300A
Number of poles3
Type of control elementPush button
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
With switched-off indicatorYes
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP30
Motor drive integratedNo
Adjustment range undelayed short-circuit release9450.0 - 94500A
Position of connection for main current circuitBack side
Adjustment range short-term delayed short-circuit release6300 - 63000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA057008R1 | E6H 6300 PR121/P-LI IN=6300A 3P F H

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

6300A

Overload release current setting

2520.0 .. 6300A

Number of poles

3

Type of control element

Push button

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP30

Motor drive integrated

Adjustment range undelayed short-circuit release

9450.0 .. 94500A

Position of connection for main current circuit

Back side

Adjustment range short-term delayed short-circuit release

6300 .. 63000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Suitable for DIN rail (top hat rail) mounting