Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release7500.0 - 75000A
Rated voltage690 - 690V
Rated permanent current Iu5000A
Adjustment range short-term delayed short-circuit release3000.0 - 3000.0A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionYes
Overload release current setting2000.0 - 5000A
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact4
Number of poles4
Type of control elementPush button
Position of connection for main current circuitBack side
Motor drive optionalYes
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP30
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA057119R1 | E6V 5000 PR123/P-LSIG IN=5000A 4P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

7500.0 .. 75000A

Rated voltage

690 .. 690V

Rated permanent current Iu

5000A

Adjustment range short-term delayed short-circuit release

3000.0 .. 3000.0A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Overload release current setting

2000.0 .. 5000A

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

4

Number of poles

4

Type of control element

Push button

Position of connection for main current circuit

Back side

Motor drive optional

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP30

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.