Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Complete device with protection unit
Yes
Overload release current setting
2520.0 - 6300A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
No
Type of control element
Push button
Rated voltage
690 - 690V
With switched-off indicator
Yes
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
Rated permanent current Iu
6300A
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
3780.0 - 3780.0A
Degree of protection (IP)
IP30
From same serie
1SDA057164R1 | E6V 6300 PR122/P-LSI IN=6300A 4P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Complete device with protection unit
Overload release current setting
2520.0 .. 6300A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
Type of control element
Push button
Rated voltage
690 .. 690V
With switched-off indicator
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Rated permanent current Iu
6300A
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Number of poles
4
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
3780.0 .. 3780.0A
Degree of protection (IP)
IP30
From same serie