Aleta.hr
Main Product Image

1SDA058300R1 | E2S 800 PR121/P-LSIG IN=800A 3P W MP

Code: 1593773

ManufacturerRAZNO
Catalog number1SDA058300R1
Type
EAN code8015644605889

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range undelayed short-circuit release

1200.0 - 12000A

Rated voltage

690 - 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Overload release current setting

320.0 - 800A

With switched-off indicator

Yes

Rated permanent current Iu

800A

Integrated earth fault protection

Yes

Position of connection for main current circuit

Connection at separate chassis part

Type of electrical connection of main circuit

Connection at separate chassis part

Suitable for DIN rail (top hat rail) mounting

No

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

No

Number of auxiliary contacts as change-over contact

4

Number of poles

3

Degree of protection (IP)

IP30

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Yes

Motor drive integrated

No

Adjustment range short-term delayed short-circuit release

800 - 8000A

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Yes

Type of control element

Push button

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SDA058300R1 | E2S 800 PR121/P-LSIG IN=800A 3P W MP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Overload release current setting

320.0 .. 800A

With switched-off indicator

Rated permanent current Iu

800A

Integrated earth fault protection

Position of connection for main current circuit

Connection at separate chassis part

Type of electrical connection of main circuit

Connection at separate chassis part

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

4

Number of poles

3

Degree of protection (IP)

IP30

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Motor drive integrated

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Type of control element

Push button