Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA
Rated permanent current Iu1000A
Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalNo
Overload release current setting400.0 - 1000A
Number of auxiliary contacts as change-over contact4
With switched-off indicatorYes
Degree of protection (IP)IP30
Complete device with protection unitYes
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release1500.0 - 15000A
Position of connection for main current circuitBack side
Type of electrical connection of main circuitBolt connection
Number of poles3
Integrated earth fault protectionNo
Type of control elementPush button
Adjustment range short-term delayed short-circuit release600.0 - 600.0A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059181R1 | E1B 1000 PR122/P-LI IN=1000A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Rated permanent current Iu

1000A

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Overload release current setting

400.0 .. 1000A

Number of auxiliary contacts as change-over contact

4

With switched-off indicator

Degree of protection (IP)

IP30

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Motor drive optional

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Position of connection for main current circuit

Back side

Type of electrical connection of main circuit

Bolt connection

Number of poles

3

Integrated earth fault protection

Type of control element

Push button

Adjustment range short-term delayed short-circuit release

600.0 .. 600.0A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.