Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP30
Type of electrical connection of main circuitBolt connection
Type of control elementPush button
Position of connection for main current circuitBack side
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release1000 - 10000A
Adjustment range undelayed short-circuit release1500.0 - 15000A
Number of poles4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Rated permanent current Iu1000A
Overload release current setting400.0 - 1000A
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059259R1 | E2N 1000 PR121/P-LI IN=1000A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP30

Type of electrical connection of main circuit

Bolt connection

Type of control element

Push button

Position of connection for main current circuit

Back side

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Number of poles

4

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Rated permanent current Iu

1000A

Overload release current setting

400.0 .. 1000A

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.