  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu1000A
Overload release current setting400.0 - 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Adjustment range short-term delayed short-circuit release1000 - 10000A
Adjustment range undelayed short-circuit release1500.0 - 15000A
Integrated earth fault protectionNo
Type of electrical connection of main circuitConnection at separate chassis part
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact4
With switched-off indicatorYes
Position of connection for main current circuitConnection at separate chassis part
Number of poles3
Type of control elementPush button
Device constructionBuilt-in device slide-in technique (withdrawable)
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP30
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059262R1 | E2N 1000 PR121/P-LSI IN=1000A 3P W MP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

1000A

Overload release current setting

400.0 .. 1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Integrated earth fault protection

Type of electrical connection of main circuit

Connection at separate chassis part

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

With switched-off indicator

Position of connection for main current circuit

Connection at separate chassis part

Number of poles

3

Type of control element

Push button

Device construction

Built-in device slide-in technique (withdrawable)

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP30

Motor drive optional