Aleta.hr
Main Product Image

1SDA059289R1 | E2N 1000 PR123/P-LSIG IN=1000A 3P F HR

Code: 1594336

ManufacturerABB
Catalog number1SDA059289R1
EAN code8015644616502

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1000A
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Integrated earth fault protectionYes
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release1500.0 - 15000A
With switched-off indicatorYes
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact4
Degree of protection (IP)IP30
With under voltage releaseNo
Position of connection for main current circuitBack side
Number of poles3
Overload release current setting400.0 - 1000A
Adjustment range short-term delayed short-circuit release600.0 - 600.0A
Motor drive integratedNo
Motor drive optionalYes
Type of control elementPush button
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059289R1 | E2N 1000 PR123/P-LSIG IN=1000A 3P F HR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Integrated earth fault protection

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

4

Degree of protection (IP)

IP30

With under voltage release

Position of connection for main current circuit

Back side

Number of poles

3

Overload release current setting

400.0 .. 1000A

Adjustment range short-term delayed short-circuit release

600.0 .. 600.0A

Motor drive integrated

Motor drive optional

Type of control element

Push button

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.