Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting400.0 - 1000A
Rated permanent current Iu1000A
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release1500.0 - 15000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release1000 - 10000A
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of poles4
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
Device constructionBuilt-in device fixed built-in technique
Position of connection for main current circuitBack side
Type of control elementPush button
Degree of protection (IP)IP30
Motor drive integratedNo
Motor drive optionalYes
Complete device with protection unitYes
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059303R1 | E2S 1000 PR121/P-LI IN=1000A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

400.0 .. 1000A

Rated permanent current Iu

1000A

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Number of poles

4

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

Device construction

Built-in device fixed built-in technique

Position of connection for main current circuit

Back side

Type of control element

Push button

Degree of protection (IP)

IP30

Motor drive integrated

Motor drive optional

Complete device with protection unit

Rated voltage

690 .. 690V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.