Aleta.hr
Main Product Image

1SDA059312R1 | E2S 1000 PR121/P-LSIG IN=1000A 4P W MP

Code: 1594355

ManufacturerRAZNO
Catalog number1SDA059312R1
Type
EAN code8015644616731

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Rated voltage

690 - 690V

Adjustment range short-term delayed short-circuit release

1000 - 10000A

Device construction

Built-in device slide-in technique (withdrawable)

Type of electrical connection of main circuit

Connection at separate chassis part

Integrated earth fault protection

Yes

Overload release current setting

400.0 - 1000A

Adjustment range undelayed short-circuit release

1500.0 - 15000A

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

4

With switched-off indicator

Yes

Position of connection for main current circuit

Connection at separate chassis part

Complete device with protection unit

Yes

DIN rail (top hat rail) mounting optional

No

Motor drive integrated

No

Degree of protection (IP)

IP30

Suitable for DIN rail (top hat rail) mounting

No

Type of control element

Push button

Motor drive optional

Yes

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SDA059312R1 | E2S 1000 PR121/P-LSIG IN=1000A 4P W MP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Device construction

Built-in device slide-in technique (withdrawable)

Type of electrical connection of main circuit

Connection at separate chassis part

Integrated earth fault protection

Overload release current setting

400.0 .. 1000A

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

4

With switched-off indicator

Position of connection for main current circuit

Connection at separate chassis part

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Motor drive integrated

Degree of protection (IP)

IP30

Suitable for DIN rail (top hat rail) mounting

Type of control element

Push button

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.