Aleta.hr
Main Product Image

1SDA059353R1 | E3H 1000 PR121/P-LSIG IN=1000A 3P F HR

Code: 1594392

ManufacturerABB
Catalog number1SDA059353R1
EAN code8015644617141

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range undelayed short-circuit release1500.0 - 15000A
Rated permanent current Iu1000A
Adjustment range short-term delayed short-circuit release1000 - 10000A
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
Integrated earth fault protectionYes
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Overload release current setting400.0 - 1000A
Complete device with protection unitYes
Position of connection for main current circuitBack side
Motor drive integratedNo
Number of auxiliary contacts as change-over contact4
Number of poles3
Type of control elementPush button
Motor drive optionalYes
Degree of protection (IP)IP30
With switched-off indicatorYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059353R1 | E3H 1000 PR121/P-LSIG IN=1000A 3P F HR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Rated permanent current Iu

1000A

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Overload release current setting

400.0 .. 1000A

Complete device with protection unit

Position of connection for main current circuit

Back side

Motor drive integrated

Number of auxiliary contacts as change-over contact

4

Number of poles

3

Type of control element

Push button

Motor drive optional

Degree of protection (IP)

IP30

With switched-off indicator

Device construction

Built-in device fixed built-in technique

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.