  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1000A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitBack side
Adjustment range short-term delayed short-circuit release600.0 - 600.0A
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact4
Integrated earth fault protectionYes
With switched-off indicatorYes
Motor drive integratedNo
Adjustment range undelayed short-circuit release1500.0 - 15000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Type of control elementPush button
Overload release current setting400.0 - 1000A
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP30
Number of poles4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059367R1 | E3H 1000 PR122/P-LSIG IN=1000A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Back side

Adjustment range short-term delayed short-circuit release

600.0 .. 600.0A

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Motor drive optional

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

4

Integrated earth fault protection

With switched-off indicator

Motor drive integrated

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Type of control element

Push button

Overload release current setting

400.0 .. 1000A

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP30

Number of poles

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.