Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
400.0 - 1000A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
600.0 - 600.0A
Integrated earth fault protection
Yes
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA059378R1 | E3H 1000 PR123/P-LSIG IN=1000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
400.0 .. 1000A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
600.0 .. 600.0A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP30
Motor drive optional
From same serie