1SDA059387R1 | E3S 1000 PR121/P-LI IN=1000A 4P F HR

Code: 1594422

ManufacturerABB
Catalog number1SDA059387R1
EAN code8015644617486

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1000A
Rated voltage690 - 690V
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release1500.0 - 15000A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release1000 - 10000A
Device constructionBuilt-in device fixed built-in technique
Overload release current setting400.0 - 1000A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact4
Complete device with protection unitYes
Position of connection for main current circuitBack side
Number of poles4
With switched-off indicatorYes
Degree of protection (IP)IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz75kA
Motor drive integratedNo
Type of control elementPush button
Motor drive optionalYes
Type of electrical connection of main circuitBolt connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059387R1 | E3S 1000 PR121/P-LI IN=1000A 4P F HR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Rated voltage

690 .. 690V

Integrated earth fault protection

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Device construction

Built-in device fixed built-in technique

Overload release current setting

400.0 .. 1000A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

Complete device with protection unit

Position of connection for main current circuit

Back side

Number of poles

4

With switched-off indicator

Degree of protection (IP)

IP30

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

75kA

Motor drive integrated

Type of control element

Push button

Motor drive optional

Type of electrical connection of main circuit

Bolt connection