Technical specifications
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1000 - 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Overload release current setting
400.0 - 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Motor drive integrated
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Number of poles
3
Motor drive optional
Yes
Integrated earth fault protection
No
With switched-off indicator
Yes
Rated permanent current Iu
1000A
From same serie
1SDA059390R1 | E3S 1000 PR121/P-LSI IN=1000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1000 .. 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Overload release current setting
400.0 .. 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Motor drive integrated
Degree of protection (IP)
IP30
Complete device with protection unit
Number of poles
3
Motor drive optional
Integrated earth fault protection
With switched-off indicator
Rated permanent current Iu
1000A