Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz75kA
Adjustment range undelayed short-circuit release1500.0 - 15000A
Integrated earth fault protectionYes
Overload release current setting400.0 - 1000A
Rated permanent current Iu1000A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release600.0 - 600.0A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact4
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
Number of poles4
Position of connection for main current circuitBack side
Motor drive integratedNo
Type of control elementPush button
Degree of protection (IP)IP30
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059407R1 | E3S 1000 PR122/P-LSIG IN=1000A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

75kA

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Integrated earth fault protection

Overload release current setting

400.0 .. 1000A

Rated permanent current Iu

1000A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

600.0 .. 600.0A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Number of poles

4

Position of connection for main current circuit

Back side

Motor drive integrated

Type of control element

Push button

Degree of protection (IP)

IP30

Motor drive optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.