Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1000A
Overload release current setting
400.0 - 1000A
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
With switched-off indicator
Yes
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
600.0 - 600.0A
DIN rail (top hat rail) mounting optional
No
Number of poles
3
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Type of control element
Push button
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
From same serie
1SDA059418R1 | E3S 1000 PR123/P-LSIG IN=1000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1000A
Overload release current setting
400.0 .. 1000A
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
With switched-off indicator
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
600.0 .. 600.0A
DIN rail (top hat rail) mounting optional
Number of poles
3
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Type of control element
Push button
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit