Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
600.0 - 600.0A
Overload release current setting
400.0 - 1000A
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 - 15000A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
No
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Motor drive optional
Yes
With switched-off indicator
Yes
From same serie
1SDA059420R1 | E3S 1000 PR123/P-LSIG IN=1000A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
600.0 .. 600.0A
Overload release current setting
400.0 .. 1000A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Motor drive optional
With switched-off indicator
From same serie