Rated insulation voltage Ui440V
Rated voltage230V
Built-in depth69mm
Frequency50 - 60Hz
Rated current1.6A
Voltage typeAC/DC
Release characteristicK
Suitable for flush-mounted installationNo
Pollution degree3
Over voltage category3
Concurrently switching neutral conductorNo
Width in number of modular spacings1
Degree of protection (IP)IP20
Number of protected poles1
Current limiting class3
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271061R0257 | S201M-K1,6UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Rated voltage

230V

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated current

1.6A

Voltage type

AC/DC

Release characteristic

K

Suitable for flush-mounted installation

Pollution degree

3

Over voltage category

3

Concurrently switching neutral conductor

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Number of protected poles

1

Current limiting class

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.