Aleta.hr
Main Product Image

1SDA064615R1 | E3H 1600 PR122/DC IN=1600A 4P F VR<HR

Code: 1613191

ManufacturerABB
Catalog number1SDA064615R1
EAN code8015644675080

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu1600A
Overload release current setting640 - 1600A
Power loss184W
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitBack side
Number of poles4
Adjustment range undelayed short-circuit release2400 - 24000A
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Rated voltage1000 - 1000V
Type of control elementPush button
Number of auxiliary contacts as normally open contact0
With switched-off indicatorYes
Motor drive integratedNo
Degree of protection (IP)IP30
Complete device with protection unitYes
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA064615R1 | E3H 1600 PR122/DC IN=1600A 4P F VR<HR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

1600A

Overload release current setting

640 .. 1600A

Power loss

184W

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Back side

Number of poles

4

Adjustment range undelayed short-circuit release

2400 .. 24000A

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Rated voltage

1000 .. 1000V

Type of control element

Push button

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Motor drive integrated

Degree of protection (IP)

IP30

Complete device with protection unit

Motor drive optional

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.