Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Integrated earth fault protection
No
Rated permanent current Iu
2500A
Rated voltage
750 - 750V
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Overload release current setting
1000.0 - 2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Yes
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
Motor drive integrated
No
From same serie
1SDA064623R1 | E3N 2500 PR122/DC IN=2500A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Integrated earth fault protection
Rated permanent current Iu
2500A
Rated voltage
750 .. 750V
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Overload release current setting
1000.0 .. 2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Motor drive integrated
From same serie