Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2000A
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Rated voltage
1000 - 1000V
With switched-off indicator
Yes
With under voltage release
No
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive optional
Yes
Overload release current setting
800.0 - 2000A
Motor drive integrated
No
Degree of protection (IP)
IP30
From same serie
1SDA064634R1 | E3H 2000 PR122/DC IN=2000A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2000A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Rated voltage
1000 .. 1000V
With switched-off indicator
With under voltage release
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Motor drive optional
Overload release current setting
800.0 .. 2000A
Motor drive integrated
Degree of protection (IP)
IP30