Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
Integrated earth fault protection
No
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
750 - 750V
Number of poles
3
Overload release current setting
1000.0 - 2500A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Motor drive integrated
No
With under voltage release
No
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
From same serie
1SDA064648R1 | E4S 2500 PR122/DC IN=2500A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
Integrated earth fault protection
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Rated voltage
750 .. 750V
Number of poles
3
Overload release current setting
1000.0 .. 2500A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Motor drive integrated
With under voltage release
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP30