Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
3200A
Rated voltage
750 - 750V
Overload release current setting
1280.0 - 3200A
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Motor drive integrated
No
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
No
1SDA064649R1 | E4S 3200 PR122/DC IN=3200A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
3200A
Rated voltage
750 .. 750V
Overload release current setting
1280.0 .. 3200A
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Motor drive integrated
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
We use cookies to enhance your experience.