Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
3200A
Integrated earth fault protection
No
Overload release current setting
1280.0 - 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Rated voltage
1000 - 1000V
Complete device with protection unit
Yes
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
1SDA064655R1 | E4H/F 3200 PR122/DC IN=3200A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
3200A
Integrated earth fault protection
Overload release current setting
1280.0 .. 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Rated voltage
1000 .. 1000V
Complete device with protection unit
Motor drive optional
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4