Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Overload release current setting320.0 - 800A
Degree of protection (IP)IP30
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu800A
Number of auxiliary contacts as change-over contact4
Rated voltage750 - 750V
Motor drive integratedNo
Position of connection for main current circuitBack side
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1200.0 - 12000A
DIN rail (top hat rail) mounting optionalNo
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
With under voltage releaseNo
Integrated earth fault protectionNo
Type of control elementPush button
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA064668R1 | E2B 800 PR123/DC IN=800A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Overload release current setting

320.0 .. 800A

Degree of protection (IP)

IP30

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

800A

Number of auxiliary contacts as change-over contact

4

Rated voltage

750 .. 750V

Motor drive integrated

Position of connection for main current circuit

Back side

Number of auxiliary contacts as normally open contact

0

Motor drive optional

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

With under voltage release

Integrated earth fault protection

Type of control element

Push button