Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
1000A
Rated voltage
750 - 750V
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Overload release current setting
400.0 - 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Number of poles
3
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Motor drive integrated
No
Motor drive optional
Yes
With switched-off indicator
Yes
1SDA064679R1 | E2B 1000 PR123/DC IN=1000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
1000A
Rated voltage
750 .. 750V
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Overload release current setting
400.0 .. 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Complete device with protection unit
Number of poles
3
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Motor drive integrated
Motor drive optional
With switched-off indicator