Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated voltage
750 - 750V
Overload release current setting
640.0 - 1600A
Integrated earth fault protection
No
Rated permanent current Iu
1600A
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
With switched-off indicator
Yes
Type of control element
Push button
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
1SDA064682R1 | E2N 1600 PR123/DC IN=1600A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated voltage
750 .. 750V
Overload release current setting
640.0 .. 1600A
Integrated earth fault protection
Rated permanent current Iu
1600A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
With switched-off indicator
Type of control element
Push button
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4