Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
1600A
Rated voltage
1000 - 1000V
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
With switched-off indicator
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Overload release current setting
640.0 - 1600A
Number of auxiliary contacts as normally open contact
0
1SDA064687R1 | E2N 1600 PR123/DC IN=1600A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
1600A
Rated voltage
1000 .. 1000V
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
Motor drive optional
With switched-off indicator
Complete device with protection unit
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Overload release current setting
640.0 .. 1600A
Number of auxiliary contacts as normally open contact
0
We use cookies to enhance your experience.