Catalog number1SDA064707R1
EAN code8015644676001

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
With integrated under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact4
Rated voltage750 - 750V
Number of poles3
With switched-off indicatorYes
Position of connection for main current circuitConnection at separate chassis part
Type of electrical connection of main circuitConnection at separate chassis part
DIN rail (top hat rail) mounting optionalNo
Overload release current setting400.0 - 1000A
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Adjustment range undelayed short-circuit release1500.0 - 15000A
Type of control elementPush button
Motor drive optionalYes
Complete device with protection unitYes
Degree of protection (IP)IP30
Rated permanent current Iu1000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA064707R1 | E3N 1000 PR123/DC IN=1000A 3P W MP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

With integrated under voltage release

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

Rated voltage

750 .. 750V

Number of poles

3

With switched-off indicator

Position of connection for main current circuit

Connection at separate chassis part

Type of electrical connection of main circuit

Connection at separate chassis part

DIN rail (top hat rail) mounting optional

Overload release current setting

400.0 .. 1000A

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Type of control element

Push button

Motor drive optional

Complete device with protection unit

Degree of protection (IP)

IP30

Rated permanent current Iu

1000A

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.