Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated voltage
750 - 750V
With switched-off indicator
Yes
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
With under voltage release
No
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Degree of protection (IP)
IP30
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
640.0 - 1600A
Complete device with protection unit
Yes
From same serie
1SDA064712R1 | E3H 1600 PR123/DC IN=1600A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated voltage
750 .. 750V
With switched-off indicator
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
With under voltage release
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Degree of protection (IP)
IP30
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
640.0 .. 1600A
Complete device with protection unit