Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated voltage
1000 - 1000V
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
800A
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Complete device with protection unit
Yes
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Overload release current setting
320.0 - 800A
From same serie
1SDA064715R1 | E3N 800 PR123/DC IN=800A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated voltage
1000 .. 1000V
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
800A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Complete device with protection unit
Motor drive optional
DIN rail (top hat rail) mounting optional
Motor drive integrated
With switched-off indicator
Degree of protection (IP)
IP30
Overload release current setting
320.0 .. 800A