Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
Overload release current setting800.0 - 2000A
Rated permanent current Iu2000A
Number of poles4
Position of connection for main current circuitBack side
Rated voltage1000 - 1000V
Type of control elementPush button
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Degree of protection (IP)IP30
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release3000.0 - 30000A
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA064730R1 | E4S/F 2000 PR123/DC IN=2000A 4P F VR<HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

Overload release current setting

800.0 .. 2000A

Rated permanent current Iu

2000A

Number of poles

4

Position of connection for main current circuit

Back side

Rated voltage

1000 .. 1000V

Type of control element

Push button

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Degree of protection (IP)

IP30

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Motor drive optional

Adjustment range undelayed short-circuit release

3000.0 .. 30000A

Device construction

Built-in device fixed built-in technique

With under voltage release

Complete device with protection unit