Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
2500A
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1000.0 - 2500A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
750 - 750V
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Yes
Integrated earth fault protection
No
Degree of protection (IP)
IP30
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Number of poles
3
Motor drive integrated
No
1SDA064736R1 | E4S 2500 PR123/DC IN=2500A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
2500A
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1000.0 .. 2500A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
750 .. 750V
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive optional
Integrated earth fault protection
Degree of protection (IP)
IP30
With switched-off indicator
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Number of poles
3
Motor drive integrated