Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated voltage
1000 - 1000V
Rated permanent current Iu
2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Number of poles
4
Complete device with protection unit
Yes
Overload release current setting
1000.0 - 2500A
Motor drive integrated
No
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
1SDA064741R1 | E4S/F 2500 PR123/DC IN=2500A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated voltage
1000 .. 1000V
Rated permanent current Iu
2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Number of poles
4
Complete device with protection unit
Overload release current setting
1000.0 .. 2500A
Motor drive integrated
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
Motor drive optional